Next article Search Articles Instructions for authors  Access Statistics | Citation Manager  
CASE REPORT  

 Article Access Statistics
    Viewed1914    
    Printed78    
    Emailed0    
    PDF Downloaded153    
    Comments [Add]    

Recommend this journal

Transcatheter interruption of large residual flow after device closure of "Type A" patent ductus arteriosus


Department of Paediatric Cardiology, Frontier Lifeline Hospital and Dr. K.M. Cherian Heart Foundation, Chennai, India

Correspondence Address:
Anuradha Sridhar
Department of Paediatric Cardiology, Frontier Lifeline and Dr. K.M. Cherian Heart Foundation, R30C, Ambattur Industrial Estate Road, Mogappair, Chennai
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0974-2069.99632

Rights and Permissions

Year : 2012  |  Volume : 5  |  Issue : 2  |  Page : 210-212

 

SEARCH
Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles

  Article in PDF (722 KB)
Email article
Print Article
Add to My List
We report a case of 3-year-old girl who had persistence of large residual flow following transcatheter closure of a 6 mm 'Type A' patent ductus arteriosus using a 12 × 10 mm duct occluder. Angiography revealed a large left-to-right shunt coursing through and exiting around the implanted device. Near total abolition of the residual shunt was achieved by initial implantation of an embolization coil within the duct occluder and subsequently an Amplatzer duct occluder (ADO II) adjacent to the duct occluder. This challenging case describes an additional technique of abolishing a large residual flow in and around a Nitinol duct occluder device.






[FULL TEXT] [PDF]*
 

 

 

 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 
 
 Reader Comments
 Email Alert *
  *
 * Requires registration (Free)
 
 CASE REPORT
 




Department of Paediatric Cardiology, Frontier Lifeline Hospital and Dr. K.M. Cherian Heart Foundation, Chennai, India

Correspondence Address:
Anuradha Sridhar
Department of Paediatric Cardiology, Frontier Lifeline and Dr. K.M. Cherian Heart Foundation, R30C, Ambattur Industrial Estate Road, Mogappair, Chennai
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0974-2069.99632

Rights and Permissions

We report a case of 3-year-old girl who had persistence of large residual flow following transcatheter closure of a 6 mm 'Type A' patent ductus arteriosus using a 12 × 10 mm duct occluder. Angiography revealed a large left-to-right shunt coursing through and exiting around the implanted device. Near total abolition of the residual shunt was achieved by initial implantation of an embolization coil within the duct occluder and subsequently an Amplatzer duct occluder (ADO II) adjacent to the duct occluder. This challenging case describes an additional technique of abolishing a large residual flow in and around a Nitinol duct occluder device.






[FULL TEXT] [PDF]*


        