Postoperative cerebral oximetry monitoring helps in early detection of diminished flow in Blalock–Taussig shunt


1 Department of Pediatric Intensive Care, Sir Ganga Ram Hospital, New Delhi, India
2 Department of Pediatric Cardiac Sciences, Sir Ganga Ram Hospital, New Delhi, India

Correspondence Address:
Dr. Reena Khantwal Joshi
Department of Pediatric Cardiac Sciences, Sir Ganga Ram Hospital, Rajinder Nagar, New Delhi - 110 060
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/apc.APC_182_18

Rights and Permissions

Year : 2019  |  Volume : 12  |  Issue : 2  |  Page : 169-171

 

SEARCH
Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles

  Article in PDF (521 KB)
Email article
Print Article
Add to My List
Cerebral oximeter is a noninvasive device which provides continuous monitoring of the regional cerebral saturation using near-infrared spectroscopy (NIRS). After gaining popularity as an intraoperative monitoring tool, use of NIRS monitoring has also expanded to postoperative period of congenital heart diseases now. Shunt underflow is a known complication after Blalock–Taussig (BT) shunt, which is conventionally detected by a drop in oxygen saturation and metabolic acidosis. We report a case where cerebral regional saturation monitoring by NIRS helped in early detection of low pulmonary flow state during postoperative period of neonatal BT shunt. We observed that the drop in regional cerebral oxygen saturation preceded fall in peripheral oxygen saturation during shunt underflow.






[FULL TEXT] [PDF]*
 

 

 

 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 
 
 Reader Comments
 Email Alert *
  *
 * Requires registration (Free)
 
 CASE REPORT
 




1 Department of Pediatric Intensive Care, Sir Ganga Ram Hospital, New Delhi, India
2 Department of Pediatric Cardiac Sciences, Sir Ganga Ram Hospital, New Delhi, India

Correspondence Address:
Dr. Reena Khantwal Joshi
Department of Pediatric Cardiac Sciences, Sir Ganga Ram Hospital, Rajinder Nagar, New Delhi - 110 060
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/apc.APC_182_18

Rights and Permissions

Cerebral oximeter is a noninvasive device which provides continuous monitoring of the regional cerebral saturation using near-infrared spectroscopy (NIRS). After gaining popularity as an intraoperative monitoring tool, use of NIRS monitoring has also expanded to postoperative period of congenital heart diseases now. Shunt underflow is a known complication after Blalock–Taussig (BT) shunt, which is conventionally detected by a drop in oxygen saturation and metabolic acidosis. We report a case where cerebral regional saturation monitoring by NIRS helped in early detection of low pulmonary flow state during postoperative period of neonatal BT shunt. We observed that the drop in regional cerebral oxygen saturation preceded fall in peripheral oxygen saturation during shunt underflow.