Percutaneous closure of patent ductus arteriosus with the Nit-Occlud® patent ductus arteriosus device in 268 consecutive cases


1 Department of Interventional Cardiology, Ukrainian Children's Cardiac Center, Kyiv, Ukraine
2 P. L. Shupyk National Medical Academy of Postgraduate Education, Kyiv, Ukraine
3 Department of Cardiac Surgery, Ludwig Maximilians University, Klinikum der Universität München, Munich, Germany
4 Department of Pediatric Cardiology and Intensive Care, Ludwig Maximilians University, Klinikum der Universität München, Munich, Germany

Correspondence Address:
Anja Lehner,
Department for Pediatric Cardiology and Intensive Care, Ludwig Maximilians University, Klinikum der Universität München, Marchioninistrasse 15, 81377 Munich
Germany
Login to access the Email id

Source of Support: None, Conflict of Interest: None

DOI: 10.4103/apc.APC_151_18

Background: The pfm Nit-Occlud® patent ductus arteriosus (PDA) device is well established for interventional closure of PDA. However, there are still limited data concerning its efficacy and follow-up in larger patient groups. Aims: This study aimed to evaluate the safety and efficacy of the Nit-Occlud® PDA device, implanted both through transpulmonary and transaortic approach, in a large cohort. Methods: From July 2008 to December 2015, 268 consecutive patients were admitted for transcatheter closure of a PDA and were treated with the Nit-Occlud® coil. Clinical, echocardiographic, and angiographic data were evaluated. Results: The median age was 5.2 years (range, 5 months to 62 years), and the median weight was 19.3 kg (range: 5.5–97 kg). Ten (3.7%) patients had weight <10 kg. The most common ductus types treated were Krichenko Type E and A (44.0% and 33.2%, respectively). Twelve (4.5%) patients were treated for residual shunting after surgical PDA closure. The median diameter at the narrowest point was 1.5 mm (range: 0.4–4 mm), the median size of the ampulla was 5 mm (range: 1–15 mm), and the median length was 9 mm (range: 2–25 mm). Device implantation could be successfully achieved in all cases. Closure rates documented immediately after the procedure, at 3–10 days, 1 month, and 6 months after intervention were 62%, 95.1%, 97.8%, and 98.5%, respectively. With the exception of one minor thromboembolic event, there were no procedure-related complications. Conclusion: Closure of PDA with various anatomic variations and sizes can be performed effectively and safely using the Nit-Occlud® coil.


Print this article
Search
 Back
 
  Search Pubmed for
 
    -  Maksymenko AV
    -  Kuzmenko YL
    -  Dovhaliuk AA
    -  Motrechko OO
    -  Herrmann FE
    -  Haas NA
    -  Lehner A
 Citation Manager
 Article Access Statistics
 Reader Comments
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed22    
    PDF Downloaded3    

Recommend this journal