Next article Search Articles Instructions for authors  Access Statistics | Citation Manager  
CASE REPORT  

 Article Access Statistics
    Viewed2635    
    Printed89    
    Emailed0    
    PDF Downloaded153    
    Comments [Add]    

Recommend this journal

A simple and fast technique for radiofrequency-assisted perforation of the atrial septum in congenital heart disease


Department of Pediatrics, Cardiac Diagnostic and Interventional Unit, The Hospital for Sick Children, The Labatt Family Heart Centre, University of Toronto School of Medicine, Toronto, Ontario, Canada

Correspondence Address:
Rajiv R Chaturvedi
The Hospital for Sick Children, 555 University Ave, Toronto, Ontario, M5G 1X8
Canada
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0974-2069.171405

Rights and Permissions

Year : 2016  |  Volume : 9  |  Issue : 1  |  Page : 39-41

 

SEARCH
Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles

  Article in PDF (674 KB)
Email article
Print Article
Add to My List
Radiofrequency (RF) assisted perforation of the atrial septum was performed successfully in three infants using a 0.035΂ RF wire deployed through a Williams right posterior catheter. Balloon atrial septoplasty was performed over the 0.035΂ RF wire in two of them, shortening the procedural time.






[FULL TEXT] [PDF]*
 

 

 

 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 
 
 Reader Comments
 Email Alert *
  *
 * Requires registration (Free)
 
 CASE REPORT
 




Department of Pediatrics, Cardiac Diagnostic and Interventional Unit, The Hospital for Sick Children, The Labatt Family Heart Centre, University of Toronto School of Medicine, Toronto, Ontario, Canada

Correspondence Address:
Rajiv R Chaturvedi
The Hospital for Sick Children, 555 University Ave, Toronto, Ontario, M5G 1X8
Canada
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0974-2069.171405

Rights and Permissions

Radiofrequency (RF) assisted perforation of the atrial septum was performed successfully in three infants using a 0.035΂ RF wire deployed through a Williams right posterior catheter. Balloon atrial septoplasty was performed over the 0.035΂ RF wire in two of them, shortening the procedural time.






[FULL TEXT] [PDF]*


        
Print this article     Email this article