Next article Search Articles Instructions for authors  Access Statistics | Citation Manager  
ORIGINAL ARTICLE  

 Article Access Statistics
    Viewed2716    
    Printed68    
    Emailed0    
    PDF Downloaded168    
    Comments [Add]    

Recommend this journal

Cost-effectiveness analysis of different devices used for the closure of small-to-medium-sized patent ductus arteriosus in pediatric patients


Department of Pediatrics, Division of Pediatric Cardiology, Cairo University Children's Hospital, Cairo, Egypt

Correspondence Address:
Rodina Sobhy Mandour
Division of Pediatric Cardiology, Cairo University Children's Hospital, Cairo University, 2 Aly Basha Ibrahim Street, Mounira, P.O. Box: 11111, Cairo
Egypt
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0974-2069.205138

Rights and Permissions

Year : 2017  |  Volume : 10  |  Issue : 2  |  Page : 144-151

 

SEARCH
Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles

  Article in PDF (628 KB)
Email article
Print Article
Add to My List
Aims: In this study, we examined the differences in cost and effectiveness of various devices used for the closure of small to medium sized patent ductus arteriosus (PDA). Setting and Design: We retrospectively studied 116 patients who underwent closure of small PDAs between January 2010 and January 2015. Subjects and Methods: Three types of devices were used: the Amplatzer duct occluder (ADO) II, the cook detachable coil and the Nit Occlud coil (NOC). Immediate and late complications were recorded and patients were followed up for 3 months after the procedure. Statistical Methods: All statistical calculations were performed using Statistical Package for the Social Science software. P <0.05 were considered significant. Results: We successfully deployed ADO II devices in 33 out of 35 cases, cook detachable coils in 36 out of 40 cases and NOCs in 38 out of 41 cases. In the remaining nine cases, the first device was unsuitable or embolized and required retrieval and replacement with another device. Eleven patients (9.5%) developed vascular complications and required anticoagulation therapy. Patients who had hemolysis or vascular complications remained longer in the intensive care unit, with consequently higher total cost (P = 0.016). Also, the need for a second device increased the cost per patient. Conclusions: The cook detachable coil is the most cost.effective device for closure of small.to medium.sized PDAs. Calculations of the incremental cost.effectiveness. (ICE) revealed that the Cook detachable coil had less ICE than the ADO II and NOC. The NOC was more effective with fewer complications.






[FULL TEXT] [PDF]*
 

 

 

 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 
 
 Reader Comments
 Email Alert *
  *
 * Requires registration (Free)
 
 ORIGINAL ARTICLE
 




Department of Pediatrics, Division of Pediatric Cardiology, Cairo University Children's Hospital, Cairo, Egypt

Correspondence Address:
Rodina Sobhy Mandour
Division of Pediatric Cardiology, Cairo University Children's Hospital, Cairo University, 2 Aly Basha Ibrahim Street, Mounira, P.O. Box: 11111, Cairo
Egypt
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0974-2069.205138

Rights and Permissions

Aims: In this study, we examined the differences in cost and effectiveness of various devices used for the closure of small to medium sized patent ductus arteriosus (PDA). Setting and Design: We retrospectively studied 116 patients who underwent closure of small PDAs between January 2010 and January 2015. Subjects and Methods: Three types of devices were used: the Amplatzer duct occluder (ADO) II, the cook detachable coil and the Nit Occlud coil (NOC). Immediate and late complications were recorded and patients were followed up for 3 months after the procedure. Statistical Methods: All statistical calculations were performed using Statistical Package for the Social Science software. P <0.05 were considered significant. Results: We successfully deployed ADO II devices in 33 out of 35 cases, cook detachable coils in 36 out of 40 cases and NOCs in 38 out of 41 cases. In the remaining nine cases, the first device was unsuitable or embolized and required retrieval and replacement with another device. Eleven patients (9.5%) developed vascular complications and required anticoagulation therapy. Patients who had hemolysis or vascular complications remained longer in the intensive care unit, with consequently higher total cost (P = 0.016). Also, the need for a second device increased the cost per patient. Conclusions: The cook detachable coil is the most cost.effective device for closure of small.to medium.sized PDAs. Calculations of the incremental cost.effectiveness. (ICE) revealed that the Cook detachable coil had less ICE than the ADO II and NOC. The NOC was more effective with fewer complications.