Next article Search Articles Instructions for authors  Access Statistics | Citation Manager  
BRIEF COMMUNICATION  

 Article Access Statistics
    Viewed413    
    Printed13    
    Emailed0    
    PDF Downloaded20    
    Comments [Add]    

Recommend this journal

Video-assisted thoracoscopic pacemaker lead placement in children with atrioventricular block


Children's center of arrhythmias, Veltischev Research and Clinical Institute of Pediatrics, Pirogov Russian National Research Medical University, Moscow, Russia

Correspondence Address:
Dr. Ekaterina Kulbachinskaya
119146, Komsomolskaya Str., 5-17, Moscow
Russia
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/apc.APC_93_20

Rights and Permissions

Year : 2021  |  Volume : 14  |  Issue : 1  |  Page : 67-71

 

SEARCH
Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles

  Article in PDF (1,226 KB)
Email article
Print Article
Add to My List
Background: The pacemaker lead placement is presented as one of the most appropriate procedures in children with a complete atrioventricular block (AVB). Despite the fact that video-assisted thoracic surgery (VATS) for epicardial lead placement has demonstrated positive results as to the feasibility, safety, and efficacy in adults, its role in pacemaker implantation in children remains unclear. Aim: This study sought to assess the intermediate-term outcomes of video-assisted thoracoscopic pacemaker lead placement in children with complete AVB Materials and Methods: From May 2017 to November 2019, five children with complete AVB underwent minimally invasive left ventricular (LV) lead placements via thoracoscopic video assistance approach. The procedure was performed under complex intratracheal anesthesia with single-lung ventilation, all pacing parameters were evaluated in perioperative and follow-up periods. Results: The median age of children at implantation was 3 years (range: 2 to 4 years), the median weight was 13 kg (range: 12–15 kg). All procedures were completed successfully, pacing thresholds for the active lead measured 0.3-1.1V, with R-wave amplitude of 8-18 mV and impedance of 560-1478 Ohm. Conclusion: Thoracoscopic pacemaker lead placement may provide a potential alternative to the transthoracic approach of epicardial lead placement in children with AVB.






[FULL TEXT] [PDF]*
 

 

 

 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 
 
 Reader Comments
 Email Alert *
  *
 * Requires registration (Free)
 
 BRIEF COMMUNICATION
 




Children's center of arrhythmias, Veltischev Research and Clinical Institute of Pediatrics, Pirogov Russian National Research Medical University, Moscow, Russia

Correspondence Address:
Dr. Ekaterina Kulbachinskaya
119146, Komsomolskaya Str., 5-17, Moscow
Russia
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/apc.APC_93_20

Rights and Permissions

Background: The pacemaker lead placement is presented as one of the most appropriate procedures in children with a complete atrioventricular block (AVB). Despite the fact that video-assisted thoracic surgery (VATS) for epicardial lead placement has demonstrated positive results as to the feasibility, safety, and efficacy in adults, its role in pacemaker implantation in children remains unclear. Aim: This study sought to assess the intermediate-term outcomes of video-assisted thoracoscopic pacemaker lead placement in children with complete AVB Materials and Methods: From May 2017 to November 2019, five children with complete AVB underwent minimally invasive left ventricular (LV) lead placements via thoracoscopic video assistance approach. The procedure was performed under complex intratracheal anesthesia with single-lung ventilation, all pacing parameters were evaluated in perioperative and follow-up periods. Results: The median age of children at implantation was 3 years (range: 2 to 4 years), the median weight was 13 kg (range: 12–15 kg). All procedures were completed successfully, pacing thresholds for the active lead measured 0.3-1.1V, with R-wave amplitude of 8-18 mV and impedance of 560-1478 Ohm. Conclusion: Thoracoscopic pacemaker lead placement may provide a potential alternative to the transthoracic approach of epicardial lead placement in children with AVB.