Next article Search Articles Instructions for authors  Access Statistics | Citation Manager  
ORIGINAL ARTICLE  

 Article Access Statistics
    Viewed316    
    Printed7    
    Emailed0    
    PDF Downloaded18    
    Comments [Add]    

Recommend this journal

Aortic size in children: Systolic measurements are different from diastolic measurements


1 Department of Cardiology, Nicklaus Children's Hospital, Miami, FL; Department of Cardiology, Medical University of South Carolina, Charleston, SC, USA
2 Department of Cardiology, Nicklaus Children's Hospital, Miami, FL; Department of Pediatric Cardiology, Stanford, Palo Alto, CA, USA
3 Department of Cardiology, Nicklaus Children's Hospital, Miami, FL, USA

Correspondence Address:
Dr. Mohammad F Al-mousily
Department of Cardiology, Medical University of South Carolina, 10 McClennan Banks Dr., MSC915, Charleston, SC 29425
USA
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/apc.APC_157_19

Rights and Permissions

Year : 2021  |  Volume : 14  |  Issue : 2  |  Page : 165-169

 

SEARCH
Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles

  Article in PDF (744 KB)
Email article
Print Article
Add to My List
Background : Current guidelines recommended aortic measurements during diastole in adults and during systole in children. Recent studies in adults have demonstrated noteworthy differences in aortic measurements during systole and diastole in the same subjects. In the present study, we aimed to characterize systolic and diastolic differences in aortic measurements in healthy children. Materials and Methods : This retrospective study included 272 children who had a complete echocardiogram and no heart disease. Aortic measurements at the annulus (ANN), aortic root (AOR), sinotubular junction (STJ), and ascending aorta (AAO) were performed. Systolic and diastolic values were compared by calculating the mean systolic to diastolic (SD) percent difference for each segment; if the SD difference was >5%, it was considered clinically important. Similar measurements were conducted by another observer in 18% of the subjects. Results : Systolic measurements were larger than diastolic measurements with mean SD percent differences >5% (P < 0.001) for the AOR (7.3% ± 5.5%), STJ (10.24% ± 7.1%), and AAO (9.8% ± 7.4%). There was no clinically significant SD difference for the ANN. There was an excellent intraclass correlation coefficient between observers (0.982–0.995). Conclusions : Systolic measurements for the AOR, STJ, and AAO were larger than diastolic measurements. Normal reference values are utilized to design treatment for patients with abnormal aortic sizes, and the timing in the cardiovascular cycle used to decide the reference values should be equivalent to the timing used to make measurements in clinical practice. This is particularly imperative as patients transition their care from a pediatric to an adult cardiologist.






[FULL TEXT] [PDF]*
 

 

 

 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 
 
 Reader Comments
 Email Alert *
  *
 * Requires registration (Free)
 
 ORIGINAL ARTICLE
 




1 Department of Cardiology, Nicklaus Children's Hospital, Miami, FL; Department of Cardiology, Medical University of South Carolina, Charleston, SC, USA
2 Department of Cardiology, Nicklaus Children's Hospital, Miami, FL; Department of Pediatric Cardiology, Stanford, Palo Alto, CA, USA
3 Department of Cardiology, Nicklaus Children's Hospital, Miami, FL, USA

Correspondence Address:
Dr. Mohammad F Al-mousily
Department of Cardiology, Medical University of South Carolina, 10 McClennan Banks Dr., MSC915, Charleston, SC 29425
USA
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/apc.APC_157_19

Rights and Permissions

Background : Current guidelines recommended aortic measurements during diastole in adults and during systole in children. Recent studies in adults have demonstrated noteworthy differences in aortic measurements during systole and diastole in the same subjects. In the present study, we aimed to characterize systolic and diastolic differences in aortic measurements in healthy children. Materials and Methods : This retrospective study included 272 children who had a complete echocardiogram and no heart disease. Aortic measurements at the annulus (ANN), aortic root (AOR), sinotubular junction (STJ), and ascending aorta (AAO) were performed. Systolic and diastolic values were compared by calculating the mean systolic to diastolic (SD) percent difference for each segment; if the SD difference was >5%, it was considered clinically important. Similar measurements were conducted by another observer in 18% of the subjects. Results : Systolic measurements were larger than diastolic measurements with mean SD percent differences >5% (P < 0.001) for the AOR (7.3% ± 5.5%), STJ (10.24% ± 7.1%), and AAO (9.8% ± 7.4%). There was no clinically significant SD difference for the ANN. There was an excellent intraclass correlation coefficient between observers (0.982–0.995). Conclusions : Systolic measurements for the AOR, STJ, and AAO were larger than diastolic measurements. Normal reference values are utilized to design treatment for patients with abnormal aortic sizes, and the timing in the cardiovascular cycle used to decide the reference values should be equivalent to the timing used to make measurements in clinical practice. This is particularly imperative as patients transition their care from a pediatric to an adult cardiologist.